Monday 14 September 2009

POWER CABLE

22
C A B L E S
23
C A B L E S
POWER CABLE
AEMCMK F4B 0,6/1 kV
SFS 4880 HD 603-3F
EMC-shielded
4x16/10
4x25/16
4x35/16
4x50/16
4x70/21
4x95/29
4x120/41
4x150/41
4x185/57
4x240/72
4x300/88
22
25
27
31
35
39
44
48
53
59
65
590
860
1000
1300
1700
2200
2750
3250
4050
5150
6350
1000 K12
1000 K14
1000 K18
500 K16
500 K20
1000 K22
1000 K20
500 K18
500 K22
500 K24
400 K22
06 030 27
06 030 28
06 224 79
06 030 30
06 224 81
06 030 32
06 224 83
06 030 37
06 224 85
06 224 86
06 224 88
REKO POWER CABLE
MCMK F4B0,6/1kV
SFS 4880 HD 603-3F and -3L
2x1,5/1,5
2x1,5/1,5
2x1,5/1,5
2x1,5/1,5
2x2,5/2,5
2x2,5/2,5
2x2,5/2,5
2x2,5/2,5
2x6/6
2x6/6
2x10/10
2x10/10
3x1,5/1,5
3x1,5/1,5
3x2,5/2,5
3x2,5/2,5
3x6/6
3x6/6
3x10/10
3x10/10
3x16/16
3x16/16
4x1,5/1,5
4x1,5/1,5
4x1,5/1,5
4x1,5/1,5
4x2,5/2,5
4x2,5/2,5
4x2,5/2,5
4x2,5/2,5
4x6/6
4x6/6
4x10/10
4x10/10
4x16/16
4x16/16
12
12
12
12
13
13
13
13
16
16
19
19
12
12
12
13
16
16
19
19
22
22
13
13
13
13
14
14
14
14
18
18
21
21
24
24
200
200
200
200
250
250
250
250
420
420
650
650
170
170
230
230
400
400
600
600
850
850
200
200
200
200
260
260
260
260
480
480
750
750
1100
1100
50 coil
100 coil
200 bobbin
1000 K8
50 coil
100 coil
150 bobbin
1000 K9
500 K8
1000 K10
500 K9
1000 K12
100 coil
1000 K8
100 coil
1000 K9
500 K8
1000 K10
500 K9
1000 K12
500 K10
1000 K14
100 coil
50 coil
150 bobbin
1000 K9
50 coil
100 coil
150 bobbin
1000 K9
500 K9
1000 K11
500 K10
1000 K12
500 K11
1000 K14
06 031 02
06 031 12
06 031 16
06 031 22
06 031 03
06 031 13
06 031 17
06 031 23
06 031 06
06 031 25
06 031 10
06 031 26
06 031 82
06 031 52
06 031 83
06 031 53
06 031 27
06 031 55
06 031 28
06 031 56
06 031 29
06 031 57
06 031 92
06 031 84
06 031 86
06 031 72
06 031 85
06 031 93
06 031 87
06 031 73
06 031 30
06 031 75
06 031 31
06 031 76
06 031 34
06 031 77
REKO
Conductor:
Insulation:
EMC-shield:
Concentric conductor:
Sheath:
Application:
16 mm² circular, solid aluminium
25...300 mm² sector shaped, stranded aluminium
95...300 mm² conductors are annealed
PVC
Core identification: table 2
Copper tape
Layer of copper wires
Black PVC
For fixed installation indoors and outdoors.
Type
AEMCMK
Outer
diameter
mm
Weight
kg/km
Standard
packing
m
Product
number
Conductor:
Insulation:
Concentric conductor:
Sheath:
Application:
1,5...6 mm² circular, solid copper
10...16 mm² circular, stranded copper
PVC. Core identification: table 2
Layer of copper wires and a copper tape
Black PVC
For fixed installation indoors and outdoors.
Type
MCMK
Outer
diameter
mm
Weight
kg/km
Standard
packing
m
Product
number

No comments: